The Bioquell Qube is a configurable isolator integrated with Bioquell’s Hydrogen Peroxide Vapor technology. From its unique design to rapid cycle times, the Bioquell Qube ensures your aseptic workspace needs are met for a safe and productive working environment.
Ideal for:
Watch Video
| Download BrochureDecontamination cycles in as little as 20 minutes; set-up from order to completed installation and validation in as few as 12 weeks
Up to three chambers (two gloves per chamber) and two material transfer areas to meet your workflow needs; positive and negative pressure capabilities
Customized validated cycles providing ISO 5/EU Grade A environment; GMP compliance; 21-CFR Part 11 software available
Four levels of environmental monitoring for your viable and nonviable particle needs; ability to incorporate the Merck Millipore Sigma Symbio Flex Sterility Pump; other distinctive options to keep you working efficiently
Built-in Bioquell Hydrogen Peroxide Vapor technology for reliable, repeatable decontamination results; easy-to-use touch-screen controls
Decontamination of materials in the main chamber while you work in another; aseptic-hold retention for typically seven days depending on your protocols
Preview key benefits and features
The strict and continual application of aseptic processing, environmental controls and monitoring are key to the approval and success of your final drug or product as a leading solution. With Bioquell’s automated, validated biodecontamination, you have confidence in your bioburden elimination of your workspace and enhancements for sterility testing.
The risk and financial impact of microbial contamination is exceptionally high during the cell-production procedure, making aseptic conditions essential to the handling of cell samples. Performing as many steps as possible under isolation and following effective disinfection is the safest method. Our flexible biodecontamination solutions allow you to maintain a secure, contaminant-free environment so you can develop and advance leading therapies and treatments.
Stringent manufacturing and compounding conditions call for leading biodecontamination solutions. Whether operated by your staff members or one of our expert onsite technicians, our fixed and portable Hydrogen Peroxide Vapor biodecontamination systems eliminate your airborne and surface contaminants in pass-throughs, airlocks and other areas for total working efficacy.
Globally accepted with hundreds of chambers currently installed and in use with world leaders in biopharmaceutical, laboratory research and biotechnology, the Bioquell Qube delivers unparalleled efficiency, reliability and ease of implementation to your aseptic environment.
The Bioquell Qube offers a rapid and reliable aseptic environment that can be used in various stages of cell and gene therapy manipulation. See some examples of the Bioquell Qube's impact here.
See how with the Bioquell Qube infographic.
Download Bioquell Qube InfographicAseptic environmental conditions with four monitoring modes ranging from manual to fully integrated particle monitoring with both viable and nonviable particle-counting options
Aseptic environmental conditions with four monitoring modes ranging from manual to fully integrated particle monitoring with both viable and nonviable particle-counting options
Up to two integrated Merck Millipore Steritest Symbio Flex sterility test pumps for improving your sterility test process, simplifying operations and freeing up workspace
Options for optimizing each chamber: full-size option for maximum storage of bottles, delivery devices, reagents and other materials during decontamination cycles; an option fitted specifically for Bioquell Qube units containing a sterility test pump
Will this offer 21-CFR Part 11 compliance?
Yes, we are able to offer an optional data logger for this purpose.
What is the internal floor of the Bioquell Qube made from?
The floor of the Bioquell Qube is constructed from 316 stainless steel to ensure resistance to scratching on the working surface.
I have a small sterility-test need right now. What happens when my needs change?
The Bioquell Qube allows you to add and expand the system as your testing needs change and grow.
How can I bring tubing or cables into the Bioquell Qube?
We have an option for fitting a floor-mounted one-inch triclover port in each chamber. This allows you to bring in liquid lines or cables securely into the body of the Bioquell Qube.
What sets the Bioquell Qube apart from traditional stainless steel options?
The Bioquell Qube is constructed of tough and hard-wearing polypropylene, which is resistant to most materials the unit is ever likely to come into contact with. Because of its construction, the Bioquell Qube can be installed and validated within 12 weeks and, in most cases with minimal invasiveness to your operation or workflow.
Can you set alarms for the temperature inside the Bioquell Qube?
Yes.
If I wish to change pressure from positive to negative, do I need to change the filters or take any additional action to ensure it is safe to use?
The Bioquell Qube can be switched between pressure regimes simply with the touch screen; no additional changes are needed.
Are there different leak tests programmed for the Bioquell Qube?
Yes, there are leak tests programmed for both positive and negative pressure.
To learn more about how Bioquell can fit your solution, please contact us.
Bioquell Inc.
702 Electronic Dr. Suite 200
Horsham, PA 19044
+1 215 682 0225
[email protected]
Bioquell UK Ltd
52 Royce Cl,
Andover SP10 3TS, UK
+44 (0)1264 835 835
[email protected]
19